BTW, DOWNLOAD part of Pass4cram D-SNC-DY-00 dumps from Cloud Storage: https://drive.google.com/open?id=1D92T6kB2U5AbuzUfaIYuwyAEopZCPaqQ
Pass4cram is one of the leading platforms that has been helping Dell SONiC Deploy Exam (D-SNC-DY-00) exam candidates for many years. Over this long time period we have helped D-SNC-DY-00 exam candidates in their preparation. They got help from Pass4cram Dell SONiC Deploy Exam practice questions and easily got success in the final D-SNC-DY-00 Certification Exam. You can also trust Pass4cram D-SNC-DY-00 exam dumps and start preparation with complete peace of mind and satisfaction.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
Topic 5 |
|
>> D-SNC-DY-00 Reliable Exam Preparation <<
Today is the best time to become competitive and updated in the market. You can do this easily. Just enroll in the D-SNC-DY-00 exam and start D-SNC-DY-00 exam preparation with Dell SONiC Deploy Exam exam dumps. Download the Exams. Solutions EMC D-SNC-DY-00 Exam Dumps after paying an affordable D-SNC-DY-00 exam questions charge and start this journey without wasting further time.
NEW QUESTION # 23
Refer to the exhibits.
PC1 has a valid address on the 192.168.10.0 network, and PC2 has a valid address on the 192.168.20.0 network.
What happens when a ping command is issued between PC1 and PC2?
Answer: A
Explanation:
* Network Topology Analysis:
* PC1 is on VLAN 10 with an IP address in the 192.168.10.0/24 subnet.
* PC2 is on VLAN 20 with an IP address in the 192.168.20.0/24 subnet.
* The network uses OSPF for routing between the switches.
* The OSPF area is 0, and all switches have loopback interfaces for OSPF.
* Routing Table Examination (from switch1):
* The show ip route command output from switch1 provides a detailed look at the routing table.
* Routes to the 192.168.10.0/24 network (directly connected via Vlan10) are present.
* No routes to the 192.168.20.0/24 network are listed in switch1's routing table.
* Explanation:
* For PC1 to communicate with PC2, switch1 must have a route to the 192.168.20.0/24 network.
* The absence of a route to the 192.168.20.0/24 network in switch1's routing table means that switch1 cannot forward packets destined for 192.168.20.0/24.
* Therefore, any ping from PC1 to PC2 will be unsuccessful as switch1 does not know how to route packets to PC2's network.
* Verification with Dell SONiC:
* In Dell SONiC environments, OSPF is configured to ensure dynamic routing.
* The configuration must include all necessary networks for inter-switch routing.
* If a network (like 192.168.20.0/24) is not included in OSPF configurations on switch1, routes to that network will not be advertised or learned, leading to failed connectivity tests like the ping from PC1 to PC2.
References:
* Dell Enterprise SONiC Deployment Guide
* Dell Technologies Networking - SONiC
NEW QUESTION # 24
What are three characteristics of VLAN translation?
Answer: B,C,E
Explanation:
* VLAN translation is not supported on MC-LAG port channel interfaces (A): This is a restriction commonly seen in network configurations involving Multi-Chassis Link Aggregation (MC-LAG) where VLAN translation capabilities are not applied.
* Trunk or access ports can be configured as members of any VLANs that are not used as an SVLAN (B): This ensures that the VLAN configuration on trunk or access ports is flexible and does not overlap with Service VLANs (SVLANs).
* SVLAN configuration for both Q-in-Q VLAN tunneling and VLAN translation is possible on the same interface (E): This allows for complex VLAN tagging and translation configurations to be applied to the same interface, supporting advanced networking scenarios.
References:
* Dell Technologies SONiC documentation
* Dell Networking Configuration Guide
NEW QUESTION # 25
What does show interface breakout port slot/slot command display?
Answer: C
Explanation:
The show interface breakout port slot/slot command displays the breakout modes available for the specified port. Breakout modes determine how a single high-speed port can be split into multiple lower-speed ports, providing flexibility in network port configurations.
References:
* Dell Technologies SONiC Command Reference Guide
* Port Breakout Configuration Guide
NEW QUESTION # 26
A deployment requires routing and dynamic access control lists. What bundle must be used for this deployment?
Answer: D
Explanation:
For a deployment that requires routing and dynamic access control lists, the appropriate bundle to use is the Enterprise Standard bundle. This bundle includes advanced routing capabilities and supports dynamic access control lists for comprehensive network management and security.
References:
* Dell Technologies SONiC documentation
* Dell Networking Bundle Configuration Guide
NEW QUESTION # 27
VLAN 40 is configured in Switch A with an anycast-address of 192.168.40.254/24. The ARP neighbor suppression is enabled. Use the simulator to create a VTEP named vtep1 and assign an IP address of
10.10.10.1. Map the VNI 400 to VLAN 40.
Answer:
Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to create the VTEP and map the VNI to the VLAN:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create VTEP Interface:
SwitchA(config)# interface vtep1
SwitchA(config-if-vtep1)# ip address 10.10.10.1/24
SwitchA(config-if-vtep1)# exit
* Map VNI 400 to VLAN 40:
SwitchA(config)# vlan 40
SwitchA(config-vlan)# vn-segment 400
SwitchA(config-vlan)# exit
* Enable ARP Neighbor Suppression:
SwitchA(config)# interface Vlan40
SwitchA(config-if-Vlan40)# ip address 192.168.40.254/24
SwitchA(config-if-Vlan40)# vxlan arp-suppression
SwitchA(config-if-Vlan40)# exit
* Save Configuration:
SwitchA# write memory
* Enter Configuration Mode:
* Begin by entering the global configuration mode to make changes to the switch configuration.
* Create VTEP Interface:
* Enter the interface configuration mode for the VTEP interface named vtep1 using interface vtep1.
* Assign the IP address 10.10.10.1/24 to the VTEP interface using the ip address command.
* Exit the interface configuration mode.
* Map VNI 400 to VLAN 40:
* Enter the VLAN configuration mode for VLAN 40 using vlan 40.
* Map the VNI 400 to VLAN 40 using the vn-segment 400 command.
* Exit the VLAN configuration mode.
* Enable ARP Neighbor Suppression:
* Enter the interface configuration mode for VLAN 40 using interface Vlan40.
* Assign the anycast IP address 192.168.40.254/24 to the VLAN interface using the ip address command.
* Enable ARP neighbor suppression using the vxlan arp-suppression command.
* Exit the interface configuration mode.
* Save Configuration:
* Save the configuration to ensure the changes persist after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure a VTEP and map the VNI to VLAN 40 on Switch A, ensuring the specific requirements for IP addressing and ARP neighbor suppression are met.
NEW QUESTION # 28
......
Each product has a trial version and our products are without exception, literally means that our D-SNC-DY-00 guide torrent can provide you with a free demo when you browse our website of D-SNC-DY-00 prep guide, and we believe it is a good way for our customers to have a better understanding about our products in advance. Moreover if you have a taste ahead of schedule, you can consider whether our D-SNC-DY-00 Exam Torrent is suitable to you or not, thus making the best choice. What’s more, if you become our regular customers, you can enjoy more membership discount and preferential services.
D-SNC-DY-00 Practice Questions: https://www.pass4cram.com/D-SNC-DY-00_free-download.html
DOWNLOAD the newest Pass4cram D-SNC-DY-00 PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1D92T6kB2U5AbuzUfaIYuwyAEopZCPaqQ
Tags: D-SNC-DY-00 Reliable Exam Preparation, D-SNC-DY-00 Practice Questions, D-SNC-DY-00 Certification Dump, D-SNC-DY-00 Reliable Test Vce, D-SNC-DY-00 Valid Exam Duration